HANGZHOU XINGFA TECHNOLOGY CO., LTD.
HANGZHOU XINGFA TECHNOLOGY CO., LTD.
info@xfcable.com

Maximize Your Profits with UL 1424 FPL Shielded Fire Alarm Cable

High-demand, high-margin fire alarm cables designed for reliability and compliance.
Request a Quote Today

UL 1424 FPL Shielded Fire Alarm Cable Variants Display

XF-12AWG 2C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-12AWG 2C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-12AWG 2C SOL Shielded FPL-CL2 PVC Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


A low-resistance cable for long fire alarm circuit runs in plenum spaces, providing shielded, reliable signal transmission with solid conductors.

XF-12AWG 2/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-12AWG 2/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-12AWG 2/C STR Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Offers flexibility for easier installation in plenum areas while maintaining the current-carrying capacity and EMI protection of 12AWG stranded conductors.

XF-14AWG 2C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-14AWG 2C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-14AWG 2C SOL Shielded FPL-CL2 PVC Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


A balanced choice for standard plenum fire alarm installations, combining good current capacity with the durability of solid core wiring.

XF-14AWG 4/C SOL Shielded FPL-CL2 Fire Alarm Cable
XF-14AWG 4/C SOL Shielded FPL-CL2 Fire Alarm Cable
XF-14AWG 4/C SOL Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Supports multi-circuit signaling in a single shielded cable, ideal for connecting multiple devices or zones in air-handling spaces.

XF-14AWG 4/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-14AWG 4/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-14AWG 4/C STR Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Provides the flexibility needed for complex plenum-area installations requiring multiple, easily routable circuits with full EMI shielding.

XF-16AWG 2C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-16AWG 2C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-16AWG 2C SOL Shielded FPL-CL2 PVC Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


A cost-effective shielded cable for general plenum fire alarm loops, offering reliable performance for most commercial building applications.

XF-16AWG 2C STR Shielded FPL-CL2 Fire Alarm Cable
XF-16AWG 2C STR Shielded FPL-CL2 Fire Alarm Cable
XF-16AWG 2C STR Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Flexible stranded conductors simplify installation in tight plenum spaces while ensuring interference-free operation for critical fire systems.

XF-16AWG 4C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-16AWG 4C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-16AWG 4C SOL Shielded FPL-CL2 PVC Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Enables efficient wiring for multi-zone panels or sounder circuits within air-handling areas using durable solid-core conductors.

XF-16AWG 4C STR Shielded FPL-CL2 Fire Alarm Cable
XF-16AWG 4C STR Shielded FPL-CL2 Fire Alarm Cable
XF-16AWG 4C STR Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Ideal for projects requiring a plenum-rated, multi-conductor cable that is easy to pull and terminate in complex pathways.

XF-18AWG 2/C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-18AWG 2/C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-18AWG 2/C SOL Shielded FPL-CL2 PVC Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


A standard gauge for most fire alarm device connections in plenums, providing essential shielding with solid core reliability.

XF-18AWG 2/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 2/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 2/C STR Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


The versatile, flexible solution for connecting detectors and modules in plenum spaces where frequent movement or adjustments may occur.

XF-18AWG 4C SOL Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 4C SOL Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 4C SOL Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Perfect for wiring addressable devices or multi-function circuits in shielded, plenum-rated environments using solid conductors.

XF-18AWG 4C STR Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 4C STR Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 4C STR Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Delivers excellent flexibility and EMI protection for installing multi-conductor fire alarm networks in challenging plenum routes.

XF-18AWG 6C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-18AWG 6C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-18AWG 6C SOL Shielded FPL-CL2 PVC Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Supports complex devices or multiple circuits in a single run, designed for dense plenum areas requiring shielded solid-core cables.

XF-18AWG 6/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 6/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 6/C STR Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Facilitates the installation of sophisticated fire alarm systems with high circuit counts in plenum spaces, offering maximum routing flexibility.

XF-18AWG 8/C SOL Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 8/C SOL Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 8/C SOL Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


A high-conductor-count cable for major control panel interconnections or backbone runs within shielded, plenum-rated pathways.

XF-18AWG 8C STR Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 8C STR Shielded FPL-CL2 Fire Alarm Cable
XF-18AWG 8C STR Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


Engineered for large-scale plenum installations where numerous flexible, shielded circuits are needed for comprehensive fire system wiring.

XF-22AWG 4/C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-22AWG 4/C SOL Shielded FPL-CL2 PVC Fire Alarm Cable
XF-22AWG 4/C SOL Shielded FPL-CL2 PVC Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.


A compact, shielded solution for low-current signal and data circuits within fire alarm panels and devices installed in plenum spaces.

XF-22AWG 4/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-22AWG 4/C STR Shielded FPL-CL2 Fire Alarm Cable
XF-22AWG 4/C STR Shielded FPL-CL2 Fire Alarm Cable

Certificates: UL 1424 (CL2), CE, CPR, RoHS.

Provides essential flexibility and noise protection for intricate wiring of annunciators or communication modules in air-handling areas.

The Compliant Advantage: Your Key to U.S. & Canadian Commercial Projects

The Compliant Advantage: Your Key to U.S. & Canadian Commercial Projects

In the North American market, UL 1424 listing is not optional—it's code. Our FPL Shielded (Plenum) Fire Alarm Cable is engineered specifically to comply with this rigorous standard for cables installed in plenum spaces (air-handling areas above ceilings or in raised floors). For distributors, stocking this cable is your direct pass to participating in lucrative commercial, institutional, and high-rise projects where compliance is strictly enforced by authorities having jurisdiction (AHJs). Here’s why it’s a strategic stock item:

  • Mandatory for Market Access: This is the only cable permitted for fire alarm installations within plenum spaces per the National Electrical Code (NEC) in the U.S. and the Canadian Electrical Code (CEC). Without it, your contractor customers cannot complete most commercial jobs. You become their essential, code-compliant source.

  • Shielded Performance Meets Stringent Demands: Unlike standard FPL, our shielded variant (typically FPLP) incorporates a foil shield. This provides crucial protection against electromagnetic interference (EMI) in modern buildings packed with HVAC systems, data cables, and fluorescent lighting, preventing false alarms and ensuring signal clarity for addressable systems.

  • Circuit Integrity in a Plenum-Rated Package: The cable is constructed to not only meet flame spread and smoke density requirements for plenums but also to maintain circuit integrity during a fire event, ensuring the alarm system remains operational for safe evacuation. This dual performance is a compelling value proposition for system designers.


FAQs About UL 1424 FPL Shielded Cable

What does 'FPL' and 'Plenum Rated' specifically mean, and why is it required? What does 'FPL' and 'Plenum Rated' specifically mean, and why is it required?

FPL stands for "Fire-Protective Signaling Cable, Limited Power." Plenum Rated means the cable is certified for installation in plenum air-handling spaces without the need for metal conduit, as it meets strict flame spread (≤25) and smoke density (≤50) tests per UL 1424 and NFPA 262 (Steiner Tunnel Test). It is required by the NEC/CEC to prevent the spread of toxic smoke through a building's airflow system in the event of a fire.

When should I specify shielded FPL cable versus unshielded FPL? When should I specify shielded FPL cable versus unshielded FPL?

Specify shielded FPL cable in any plenum application where the cable run is in close proximity to potential sources of electromagnetic interference. This includes near large motorized equipment (elevators, HVAC units), parallel runs with AC power lines, or in buildings with dense wireless/RF infrastructure. The shield prevents interference from causing nuisance alarms or communication errors in sensitive addressable fire alarm control panels.

How do I verify the UL listing, and what documentation do you provide? How do I verify the UL listing, and what documentation do you provide?

Every reel is marked with the UL listing mark. We provide the official UL File Number (e.g., E123456) upon request. For distributors and contractors, we can supply a UL Product IQ Report or UL Certificate of Compliance, which are often required for project submittals to engineers and building inspectors to prove compliance.

Can this cable be used in risers or other spaces, or is it only for plenums? Can this cable be used in risers or other spaces, or is it only for plenums?

While optimized and rated for plenums, UL 1424 FPL cable is also suitable for use in riser (vertical shaft) and general purpose applications according to the NEC. However, a shielded FPLR cable would be the specific listing for riser applications if that is the primary need. Our FPLP provides broad compliance for plenum-centric projects.

Do you offer this cable in different conductor configurations (e.g., 2, 4, 6 conductor) for various fire alarm panel needs? Do you offer this cable in different conductor configurations (e.g., 2, 4, 6 conductor) for various fire alarm panel needs?

Yes. We manufacture UL 1424 FPL Shielded Cable in the standard configurations required by the industry, including 2-conductor for basic NAC (Notification Appliance Circuit) loops, 4-conductor, and multi-conductor versions for complex signaling circuits, allowing you to cover all needs for a compliant fire alarm install from one trusted source.

Ready to Find Your Perfect Cable Solution?
Ready to Find Your Perfect Cable Solution?
Contact our experts today for a personalized quote and discover the Xingfa difference in quality and reliability.
*
*
*
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy
Reject All
Accept All