Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Designed for long-distance, high-current shielded circuits in air-handling plenums requiring enhanced fire performance and signal integrity.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Provides flexible, shielded installation for power-limited plenum circuits where both EMI protection and routing ease are critical.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
A reliable shielded cable for standard two-wire device loops in plenum spaces, ensuring EMI immunity and solid conductor durability.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Offers flexible, shielded connectivity for plenum-area fire alarm devices, ideal for installations requiring frequent adjustments.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Supports multi-zone or multi-device shielded wiring within plenums, using solid conductors for stable, interference-free performance.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
A versatile, flexible solution for routing multiple shielded circuits in complex plenum pathways with ease.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
A cost-effective shielded cable for general plenum fire alarm loops, balancing performance with solid core reliability.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Delivers flexible, shielded installation for power-limited circuits in tight or demanding plenum environments.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Enables efficient, shielded multi-circuit wiring for plenum applications, utilizing durable solid-core conductors.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Ideal for projects requiring shielded, multi-conductor plenum cable that is easy to pull and terminate in confined spaces.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
The standard shielded cable for connecting most fire alarm devices in plenums, offering essential EMI protection.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Provides flexible, shielded connections for detectors and modules in plenum spaces where movement may occur.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Perfect for shielded wiring of addressable devices or sounder circuits in plenum-rated environments.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Combines flexibility with full EMI shielding for installing multi-conductor networks in challenging plenum routes.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Consolidates multiple shielded circuits for complex devices or zones within a single, plenum-rated cable.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Facilitates the installation of sophisticated shielded systems with high circuit counts in plenum spaces.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
A compact, shielded solution for low-current signal and data circuits within fire alarm panels in plenum spaces.
Certificates: UL 1424 (CL2P), CE, CPR B2ca, RoHS.
Provides essential flexibility and noise protection for intricate control wiring of ancillary systems in air-handling areas.
The “P” in FPLP stands for Plenum, but for distributors, it stands for Premium Performance and Premium Projects. This cable is specified when standard solutions are insufficient—where both fire code compliance and flawless electronic communication are mandatory. Our UL 1424 FPLP Shielded Cable integrates a continuous aluminum foil shield beneath its plenum-rated jacket, creating a definitive solution for today’s electrically noisy building environments. For your distribution business, this represents a key strategic advantage:
Capture High-Value, Low-Competition Contracts: This cable is essential for hospitals, data centers, laboratories, and high-rise buildings where addressable fire alarm systems are prevalent and susceptible to EMI from HVAC, medical imaging, or IT equipment. Offering FPLP allows you to win specialized bids that command higher margins and build your reputation as a technical solutions provider.
Solve the #1 Problem in Advanced Systems: False Alarms. In addressable loops, signal integrity is everything. The integrated shield in our FPLP cable actively prevents electromagnetic interference from corrupting digital communication between sensors and the control panel, drastically reducing the risk of costly and disruptive nuisance alarms.
One Cable, Complete Compliance & Performance: You provide your customers with a single product that satisfies the most stringent requirements: UL 1424 for plenum safety (flame/smoke), NEC Article 760 for fire alarm circuit integrity, and the unspoken requirement for reliable data transmission in a shielded environment. It simplifies their specification and your supply chain.
What is the concrete difference between FPL and FPLP cable?
Both are Plenum-rated per UL 1424. The key difference is the integrated shield. FPL is unshielded. FPLP (the ‘P’ often denotes ‘Shielded’ or ‘Plenum with Shield’ in manufacturer catalogs) includes a foil shield under the jacket. This shield is critical for protecting the low-voltage, high-sensitivity signals in addressable fire alarm systems from external electrical noise.
When is FPLP Shielded Cable explicitly required or recommended?
It is strongly recommended or may be specified by the system engineer when:
Cables are installed in shared pathways with AC power lines or large motor conduits.
In buildings with intense RF/EMI environments (near broadcast towers, industrial machinery).
For all installations of modern addressable/analog addressable fire alarm panels to ensure baseline signal purity and future-proof the installation against added interference sources.
How is the shield properly terminated and grounded during installation?
Correct installation is crucial for the shield to function. The foil shield must be properly bonded and grounded at the fire alarm control panel (FACP) end only, following the panel manufacturer’s instructions and NEC guidelines. This typically involves using a shielded connector or gland to ensure a 360-degree ground connection. We provide general guidance, but installers should always refer to system-specific manuals.
Can you provide the specific UL File Number and documentation for project submittals?
Yes. As the manufacturer, we provide the official UL File Number and can supply a UL Certificate of Compliance or Product IQ report for this specific FPLP product. This documentation is vital for your customers to include in their project manuals for approval by architects, engineers, and building inspectors.
Do you offer this in multi-conductor configurations for complex panel terminations?
Absolutely. We produce UL 1424 FPLP Shielded Cable in the configurations the market demands, including 2-conductor for NAC circuits, and 4, 6, or 8-conductor versions for running multiple circuits or for the proprietary cabling needs of specific addressable panel manufacturers.